Milk Transport Tank Buying Guide: Listed Capacities, Dimensions and Supply Scope

Buyer summary: SYS-00009 records 13 capacity configurations from 500 L to 20000 L with reference dimensions, weights and inner/outer layer thicknesses. A cooling unit is not included. Select an explicitly listed configuration, then confirm the final drawing, mounting arrangement and exact supplied equipment.

This guide organises the existing SYS-00009 transport-tank configuration table for an itemised equipment enquiry. It focuses on capacity, physical dimensions and supply scope. It does not establish temperature retention, a transport approval, a vehicle payload or a complete installed system.

Prepare a quotation checklist

Choose an explicitly listed capacity configuration

The table contains 500, 1000, 2000, 3000, 5000, 6000, 8000, 10000, 12000, 13000, 15000, 17000 and 20000 L configurations. The 500-20000 L range describes this family; it is not evidence that every intermediate capacity is supplied. Identify SYS-00009 and one listed capacity together.

Check the reference dimensions against a final drawing

The source defines the dimensions as reference L x W x H and explicitly asks buyers to confirm final dimensions for the vehicle and mounting arrangement. For example, the 500 L row is 1000 x 1000 x 900 mm, while the 5000 L row is 4200 x 1800 x 1400 mm. These dimensions do not establish mounting-hole positions, support loads, usable internal geometry or access clearances. Request the final configuration drawing and provide the intended installation constraints.

Keep recorded weight separate from vehicle loading

The 500 L row lists 300 kg, the 5000 L row 1000 kg and the 20000 L row 3000 kg. The table does not define these figures as packed shipping weight or loaded operating weight. Request the weight basis, supplied-component weights and loading information for the exact configuration. Vehicle suitability and mounting approval require a separate assessment; no payload calculation is provided here.

Keep layer thickness tied to its capacity row

The first four listed configurations, 500 through 3000 L, record an inner layer of 2 mm and outer layer of 1.2 mm. The remaining listed configurations, 5000 through 20000 L, record 3 mm and 1.5 mm respectively. These are the source table entries. They do not identify a material grade, insulation composition, pressure rating or thermal performance. Request the material and construction documentation required for the order.

Specify cooling and fittings as separate requirements

The reviewed record explicitly says the cooling unit is not included. No temperature-retention duration, cooling rate or permitted operating condition is established by the capacity table. State any temperature-control requirements and request supporting product documentation. Also confirm the actual manway, outlet, valves, vents, cleaning connections, supports and any instruments in the quoted set. No such component is assumed included from the word tank.

Compare the listed specifications

Values below belong to the linked product code. A field marked not listed requires confirmation for that SKU; it is not filled from another model.

SYS-00009 listed configuration fields

SYS-00009 listed configuration fields — product-specific catalogue fields
Specification Milk Transport Tank without Cooling Unit 500-20000 L
ERV-DF-SYS-00009
Capacity range 500-20000 L
Cooling unit Not included
Dimensions Reference L x W x H; confirm final dimensions for the vehicle and mounting arrangement
500 L configuration 1000 x 1000 x 900 mm; 300 kg; inner layer 2 mm; outer layer 1.2 mm
1000 L configuration 1500 x 1200 x 1200 mm; 400 kg; inner layer 2 mm; outer layer 1.2 mm
2000 L configuration 2100 x 1700 x 1300 mm; 600 kg; inner layer 2 mm; outer layer 1.2 mm
3000 L configuration 2500 x 1700 x 1300 mm; 800 kg; inner layer 2 mm; outer layer 1.2 mm
5000 L configuration 4200 x 1800 x 1400 mm; 1000 kg; inner layer 3 mm; outer layer 1.5 mm
6000 L configuration 5200 x 1900 x 1400 mm; 1200 kg; inner layer 3 mm; outer layer 1.5 mm
8000 L configuration 5400 x 2100 x 1400 mm; 1400 kg; inner layer 3 mm; outer layer 1.5 mm
10000 L configuration 5800 x 2100 x 1400 mm; 1600 kg; inner layer 3 mm; outer layer 1.5 mm
12000 L configuration 6300 x 2100 x 1400 mm; 1800 kg; inner layer 3 mm; outer layer 1.5 mm
13000 L configuration 6800 x 2100 x 1400 mm; 2000 kg; inner layer 3 mm; outer layer 1.5 mm
15000 L configuration 6800 x 2400 x 1400 mm; 2400 kg; inner layer 3 mm; outer layer 1.5 mm
17000 L configuration 7500 x 2400 x 1500 mm; 2800 kg; inner layer 3 mm; outer layer 1.5 mm
20000 L configuration 8400 x 2400 x 1600 mm; 3000 kg; inner layer 3 mm; outer layer 1.5 mm

Quotation checklist

  • SYS-00009, one explicitly listed capacity and quantity
  • Final labelled L x W x H drawing, mounting geometry and access constraints
  • Confirmed meaning of quoted weight; packed and loaded weights where required
  • Material grades, inner and outer layer specifications and construction documents
  • Itemised manway, valve, vent, cleaning, support and instrument supply
  • Any temperature-control requirement and matching evidence; cooling unit is not included
  • Product-specific installation, care and intended-use documents; any required transport and destination compliance evidence
  • Packing and freight dimensions, destination country and commercial terms to confirm

Frequently asked purchasing questions

Is a cooling unit supplied with SYS-00009?

No. The current specification explicitly records Cooling unit: Not included.

Is every size between 500 and 20000 L listed?

No. The source table contains 13 separate configurations. Use one of the explicitly recorded capacities and request confirmation for any other requirement.

Are the listed dimensions a final vehicle installation drawing?

No. They are reference L x W x H values. The record requires confirmation of final dimensions for the vehicle and mounting arrangement.

Can the weight column be used as a loaded vehicle weight?

No such basis is established. Confirm what each weight includes and obtain configuration-specific loading information.

Do the layer thicknesses prove insulation or temperature retention?

No. The thickness fields do not establish insulation material, a temperature-hold test or cooling performance. Request the exact construction and performance documentation.

Does this guide confirm a complete tank installation or transport approval?

No. Supplied fittings, mounting design, installation requirements and any required approvals must be confirmed for the exact order.

Browse the existing range

Milking Buckets & Containers — open individual products for their full specifications and quotation options.

Separate comparison of milking buckets and smaller milk containers.

Request a product-specific quotation

List each selected SKU, required configuration and quantity separately, with your destination country. Include the existing equipment reference, labelled measurements and the supplied parts you want confirmed.

This is a general enquiry; no product is selected automatically. Enter the product references and specifications in the form.

Request a Quote