Buyer summary: INJ-01032 records TPX plastic with a brass rod. C-type INJ-01033 and D-type INJ-01034 list PC or TPX options with SUS304 rods. L-type INJ-01040 lists TPX with a SUS304 rod. Other compared records do not name the plastic resin. Capacity lists also differ: K-type has one listed 5 ml version, while the offset model lists 100 ml. No material or capacity is transferred between SKUs.
This guide compares nine existing records in the Plastic Steel Syringe range. Its purchasing focus is plastic-material wording, rod material, letter-type identity and capacity variants. It covers different SKUs from the existing feed-type, pistol-syringe and glass-barrel guides. It gives no medicine, dose, route or administration recommendation, and makes no performance claim from a material name.
Specify TPX, PC or the unresolved plastic field by SKU
INJ-01032 and INJ-01040 record TPX. INJ-01033 and INJ-01034 record PC or TPX as plastic material options; the exact option must be confirmed for the quotation. The other compared records do not identify a resin in their specification fields. Do not describe every plastic product as TPX, merge PC and TPX into one material, or infer a sterilisation temperature or liquid compatibility from the catalogue labels.
Keep the brass rod distinct from the SUS304 rod records
INJ-01032 records Brass for the rod. INJ-01033 through INJ-01040 record SUS304 stainless steel. These are rod-material descriptions, not complete wetted-material lists or claims that the entire syringe is one material. Request the full material specification, sealing components and product-specific care instructions for the actual requirement.
Choose one explicitly listed capacity version
INJ-01032, C-type INJ-01033, D-type INJ-01034 and L-type INJ-01040 list 10, 20, 30 and 50 ml. G-type INJ-01035 and I-type INJ-01037 list 5, 10, 20 and 30 ml. J-type INJ-01038 adds 50 ml to that list. K-type INJ-01039 lists 5 ml only, while the offset INJ-01036 lists 100 ml. These are available-capacity records, not continuous adjustment ranges, guaranteed stock or delivered-dose settings.
Retain letter-type and offset references without inventing their meaning
The C and D records share the same compared capacity, material options, rod and connection fields. G and I likewise share their compared fields. Their letter labels alone do not establish a particular ergonomic advantage, fit or application. Request a labelled drawing or confirmed photograph of the exact quoted variant. INJ-01036 explicitly records Offset type, but the compared fields do not give an offset dimension.
Read printed scale as a feature, not a calibrated specification
Printed measurement scale is recorded for INJ-01035 through INJ-01040. The compared INJ-01032, INJ-01033 and INJ-01034 fields do not state that feature; omission is not proof that a scale is absent. No scale interval, accuracy tolerance, calibration result or test condition is established by the printed-scale wording. Request the actual scale and performance documentation for the chosen version.
Confirm connections, supplied parts and replacements separately
All nine records list Luer-lock. That common label does not prove needle compatibility, cross-model seal or barrel interchangeability, or included accessories. Request the end-fitting drawing, exact equipment references and written pairing confirmation. The compared fields do not establish a feed-tube kit, automatic self-filling operation or a supplied needle.
Compare the listed specifications
Values below belong to the linked product code. A field marked not listed requires confirmation for that SKU; it is not filled from another model.
Named plastic-material records
| Specification | TPX Veterinary Syringe with Brass Rod ERV-VI-INJ-01032 |
C-Type Plastic Veterinary Syringe ERV-VI-INJ-01033 |
D-Type Plastic Veterinary Syringe ERV-VI-INJ-01034 |
L-Type TPX Veterinary Syringe, 10–50 ml ERV-VI-INJ-01040 |
|---|---|---|---|---|
| Available capacities | 10 ml, 20 ml, 30 ml, 50 ml | 10 ml, 20 ml, 30 ml, 50 ml | 10 ml, 20 ml, 30 ml, 50 ml | 10 ml, 20 ml, 30 ml, 50 ml |
| Connection | Luer-lock | Luer-lock | Luer-lock | Luer-lock |
| Plastic material | TPX | Not listed; confirm for this SKU | Not listed; confirm for this SKU | TPX |
| Rod material | Brass | SUS304 stainless steel | SUS304 stainless steel | SUS304 stainless steel |
| Plastic material options | Not listed; confirm for this SKU | PC or TPX | PC or TPX | Not listed; confirm for this SKU |
| Barrel scale | Not listed; confirm for this SKU | Not listed; confirm for this SKU | Not listed; confirm for this SKU | Printed measurement scale |
G, I, J and K letter-type records
| Specification | G-Type Plastic Veterinary Syringe ERV-VI-INJ-01035 |
I-Type Plastic Veterinary Syringe ERV-VI-INJ-01037 |
J-Type Plastic Veterinary Syringe ERV-VI-INJ-01038 |
5 ml K-Type Plastic Veterinary Syringe ERV-VI-INJ-01039 |
|---|---|---|---|---|
| Available capacities | 5 ml, 10 ml, 20 ml, 30 ml | 5 ml, 10 ml, 20 ml, 30 ml | 5 ml, 10 ml, 20 ml, 30 ml, 50 ml | 5 ml |
| Connection | Luer-lock | Luer-lock | Luer-lock | Luer-lock |
| Rod material | SUS304 stainless steel | SUS304 stainless steel | SUS304 stainless steel | SUS304 stainless steel |
| Barrel scale | Printed measurement scale | Printed measurement scale | Printed measurement scale | Printed measurement scale |
100 ml offset record
| Specification | 100 ml Offset-Type Veterinary Syringe ERV-VI-INJ-01036 |
|---|---|
| Available capacities | 100 ml |
| Connection | Luer-lock |
| Rod material | SUS304 stainless steel |
| Barrel scale | Printed measurement scale |
| Design | Offset type |
Quotation checklist
- State full SKU, letter-type reference where applicable, one listed capacity and quantity.
- For INJ-01033 and INJ-01034 confirm PC or TPX explicitly; request any unlisted resin rather than borrowing it from another model.
- Keep rod material separate from the full wetted-material and seal specification.
- Request the exact variant drawing/photo, dimensions and offset measurement where needed.
- Request scale intervals and any required accuracy/calibration evidence; printed wording alone is insufficient.
- Provide existing needle/equipment references and request exact connection and replacement-part pairing confirmation.
- Confirm all included accessories and product-specific material/care documentation.
- Confirm packing, destination, availability and commercial terms.
Frequently asked purchasing questions
Are all nine products confirmed TPX?
No. TPX is recorded for INJ-01032 and INJ-01040. INJ-01033 and INJ-01034 list PC or TPX options; the other compared records do not name a resin.
Do all records list SUS304 rods?
INJ-01032 records Brass. INJ-01033 through INJ-01040 record SUS304 stainless steel. The rod is not the complete wetted-material specification.
Does every letter-type record offer 50 ml?
No. G and I list 5, 10, 20 and 30 ml, while K lists 5 ml only. J includes a 50 ml version. Use the SKU-specific table.
Do C and D have a confirmed difference in these fields?
Their compared fields are the same. Request the exact variant drawing/photo rather than inventing a design difference or assuming interchangeability.
Does printed measurement scale establish accuracy?
No interval, tolerance or calibration result is established by that feature wording. Request the actual scale and any required performance evidence.
Does the shared Luer-lock label confirm interchangeable parts?
No complete needle pairing or cross-model barrel/seal fit is established. Request exact component references and written confirmation.
Browse the existing range
Plastic Steel Syringe — open individual products for their full specifications and quotation options.
Compare the separate syringe feed-type records.
Compare pistol-format metal-component and setting records separately.
Review glass-barrel and replacement-family records separately.
Request a product-specific quotation
List each selected SKU, required configuration and quantity separately, with your destination country. Include the existing equipment reference, labelled measurements and the supplied parts you want confirmed.
This is a general enquiry; no product is selected automatically. Enter the product references and specifications in the form.